NAVIGATOR MOISTURE MAPPING METER Owner’s Manual Version 2.1 For Navigator Meters starting with Serial #11212 Delmhorst Instrument
Copyright 2007, Delmhorst Instrument Co. Page 10 of 28 TO SET THE ALARM IN BASIC SCAN MODE: 1. If you wish to set the alarm to beep after a pre-
Copyright 2007, Delmhorst Instrument Co. Page 11 of 28 Settings stored in each particular mode will not be affected by restoring defaults in a dif
Copyright 2007, Delmhorst Instrument Co. Page 12 of 28 Use the ï ð keys to toggle between residential and commercial. After you have made yo
Copyright 2007, Delmhorst Instrument Co. Page 13 of 28 TO DEFINE ROOM LOCATION AND MATERIAL DESIGNATION: 1. Using the ñ ò keys on the CREATE JOB
Copyright 2007, Delmhorst Instrument Co. Page 14 of 28 Note: The default selection is OAK for the floor and SHEETROCK for the wall and ceiling. I
Copyright 2007, Delmhorst Instrument Co. Page 15 of 28 This screen contains the following information: Job # and ID, current location (LOC), numbe
Copyright 2007, Delmhorst Instrument Co. Page 16 of 28 3. The default status of the alarm is “OFF.” Press the SELECT key to turn it on. 4.
Copyright 2007, Delmhorst Instrument Co. Page 17 of 28 At any time, you may modify Temperature (T), location (LOC), or switch to SCAN mode (GOTO S
Copyright 2007, Delmhorst Instrument Co. Page 18 of 28 Note: Memory deletion and restoring defaults are both irreversible. • EXIT: This menu opt
Copyright 2007, Delmhorst Instrument Co. Page 19 of 28 all have ample delays built in to allow the other link components to come online in any seq
Copyright 2007, Delmhorst Instrument Co. Page 2 of 28 TABLE OF CONTENTS PAGE GENERAL DESCRIPTION & FEATURES 4 OPERAT
Copyright 2007, Delmhorst Instrument Co. Page 20 of 28 • Return to Main Menu: This menu option returns the meter to Main Menu. The meter also re
Copyright 2007, Delmhorst Instrument Co. Page 21 of 28 are 10, 20, 30sec. It is recommended that the backlight delay be set to the minimum amount
Copyright 2007, Delmhorst Instrument Co. Page 22 of 28 ⇒ Set the meter’s parameters as described previously in the owners’ manual. If the speci
Copyright 2007, Delmhorst Instrument Co. Page 23 of 28 will move into a hygroscopic (wood) floor, or build-up pressure under a non-breathing synth
Copyright 2007, Delmhorst Instrument Co. Page 24 of 28 TESTING DRYWALL ⇒ Set the meter scale for Sheetrock® as described in the Create/Modify a
Copyright 2007, Delmhorst Instrument Co. Page 25 of 28 CARE OF YOUR METER Ø Store your meter in a clean, dry place. The protective carrying cas
Copyright 2007, Delmhorst Instrument Co. Page 26 of 28 SERVICE FOR YOUR METER Ø Before sending in your meter we recommend you give one of our tr
Copyright 2007, Delmhorst Instrument Co. Page 27 of 28 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees the Na
Copyright 2007, Delmhorst Instrument Co. Page 28 of 28 APPENDIX A: Room list – Residential Jobs Number Abbreviation Description Page 1 1 LR L
Copyright 2007, Delmhorst Instrument Co. Page 3 of 28 TESTING CONCRETE SLABS 23 TESTING INSULATION 24 TESTING DRYWALL 24 CARE OF YOUR
Copyright 2007, Delmhorst Instrument Co. Page 4 of 28 GENERAL DESCRIPTION/FEATURES Thank you for your purchase of Delmhorst Instrument Co’s newly
Copyright 2007, Delmhorst Instrument Co. Page 5 of 28 OPERATING INSTRUCTIONS -User Guide- This guide provides step-by-step instructions on poweri
Copyright 2007, Delmhorst Instrument Co. Page 6 of 28 INSTALLING THE BATTERY: The battery compartment is located on the underside of the case, at
Copyright 2007, Delmhorst Instrument Co. Page 7 of 28 TO POWER THE METER ON: To turn the meter on, press and hold the SELECT button for approx. 2
Copyright 2007, Delmhorst Instrument Co. Page 8 of 28 3. Use the òkey to highlight the default material (Oak) if you wish to change it to a diffe
Copyright 2007, Delmhorst Instrument Co. Page 9 of 28 TO CHANGE THE TEMPERATURE CORRECTION: Navigator defaults to a temperature of 70ºF. As wood
Commentaires sur ces manuels