OWNER’S MANUAL
MODEL G-34 MOISTURE DETECTOR FOR BALED HOPS
INTRODUCTION
Thank you for purchasing the Delmhorst model G-34 Moisture Detector. The G-
34 is a rugged, reliable instrument that enables you to easily check moisture
levels in baled hops to assure quality and safe storage. Features include:
Easy-to-read analog display.
Moisture Range: 7%-14%.
Built-in battery and calibration check.
Auto-shutoff timer to extend battery life.
Sturdy plastic carrying case.
2-9V batteries (included)
1-year warranty on the meter, 90DD on all electrodes
OPERATION
1. To check battery voltage, push the switch down to the “OFF” position and
hold. The batteries are OK if the needle moves beyond “11” (BATT OK”).
The 9-volt batteries are located in the compartment on the case bottom.
2. To check the meter calibration, push the switch to the “ON” position and
hold. The meter is in calibration if it reads “13.5” on the dial. A tolerance
of + 0.5 is acceptable. An optional external resistance standard (part
no.MCS-44) is also available. Please contact Delmhorst or your local
dealer to purchase.
To turn the meter on, push the switch to the “ON” position and release.
The meter remains on for 4 minutes. The auto-timer is reactivated for 4
minutes with each subsequent test with a reading of 8% or higher. If
readings are below 8%, push the switch “ON” from time to time to prevent
the meter from turning “OFF” automatically. The meter may be turned off
manually by pushing the switch to the “OFF” position. When the meter is
“ON”, the needle rests below the 6% mark.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1

1 OWNER’S MANUAL MODEL G-34 MOISTURE DETECTOR FOR BALED HOPS INTRODUCTION Thank you for purchasing the Delmhorst model G-34 Moisture Detector.

Page 2

2 3. To check the %MC of bales connect the 830-2 (10 in) or 830-5 (12 in) prod to the H-4 handle. Connect the H-4 to the input connector marked “

Page 3

3  Clean the meter and electrodes with any biodegradable cleaner. Use the cleaner sparingly and on external parts only. Keep cleaner out of the

Page 4

4 The express warranty set forth above constitutes the entire warranty with respect to Delmhorst meters and electrodes and no other warranty, writte

Commentaires sur ces manuels

Pas de commentaire