J-2000
owners manual
WHEN ACCURACY IS THE POINT.
®
TM
Vue de la page 0
1 2 3 4 5 6 ... 12 13

Résumé du contenu

Page 1 - WHEN ACCURACY IS THE POINT

J-2000owners manualWHEN ACCURACY IS THE POINT.®TM

Page 2 - TABLE OF CONTENTS

PIN TALKThere are two types of contact pins - uninsulated, which wereprovided with your meter, and insulated. When using uninsulatedpins, push them i

Page 3 - DELMHORST J-2000

SERVICE FOR YOUR METERhBefore sending in your meter we recommend you giveone of our trained technicians a call. Many timestroubleshooting can be taken

Page 4 - @ and read button !

WARRANTYDelmhorst Instrument Co., referred to hereafter asDelmhorst, guarantees its J-2000 meter for one year fromdate of purchase and any optional el

Page 5

51 Indian Lane EastTowaco, NJ 07082(877)-DELMHORSTwww.delmhorst.come-mail - [email protected]©2006, Delmhorst Instrument Co.510INS-0003 REV. 11/06

Page 6 - Species Code Chart

TABLE OF CONTENTS2 J-2000 Features3 Before You Begin3 Check Calibration4 Set Species5 Species Code Chart6 Set Temperature7 Set Pin Calibration7 Taking

Page 7 - Set Temperature Mode

^J-2000 FEATUREShResistance technology recognized worldwide as the mostaccurate method for measuring moistureh6% to 40% moisture rangehDigital readout

Page 8

BEFORE YOU BEGINButton Functions! READ BUTTON - Reads the Percent MoistureContent value (%MC), corrected for temperatureand species.@ CALIBRATION CHEC

Page 9

SET SPECIESThe J-2000 defaults to Species Code #1 - Douglas Fir - theUSDA standard and basis for all calibrations. Because theelectrical characteristi

Page 10 - CARE OF YOUR METER

Species Code ChartCODE / SPECIES CODE / SPECIES1 Fir, Douglas 25 Magnolia2 Pine, Southern 26 Mahogany, African (also Khaya)3 SPF 27 Mahogany, Honduras

Page 11 - SERVICE FOR YOUR METER

SET TEMPERATUREThe J-2000 defaults to a temperature of 70ºF. As woodtemperature increases, its electrical resistance decreases andindicated moisture c

Page 12 - WARRANTY

SET PIN CALIBRATIONThe basic factory calibration of the J-2000 is for use withuninsulated pins – either the integral pins ^ or with anoptional externa

Page 13

INFORMATION ABOUT YOUR READINGS Readings below 6% will be displayed as a numeric value, (-##.#), and will not be added to accumulation. A readingbelow